The topic of the thermal and acoustic insulation is on the agenda in all industrial, productive, civil,naval areas. An increasing challenge, pushed also from a greater and chasing sensitization towards the problems of environment, ecology, and from regulations and laws as regards.
|
INSULATION OF NEW GENERATIONSYSTEMS APPLIABLE LIKE COMMON PAINTSLOW THICKNESS: max 8 mmRESISTANT TILL 700°CcTEMPERATURE REDUCTION: 80 %NO NANOTECHNOLOGIESMADE IN ITALYINDUSTRIAL APPLICATIONS![]() Valves and pipings Industrial furnaces Rafineries, Foudries, Oils and petrochemicals Automotive, industrial vehicles, bus: inside car, engine
MARINE APPLICATIONS![]() Air conditioningsystems(elimination of the condenses)
CIVIL APPLICATIONS![]() Internal insulation Floor insualtion Windows insulation |
Our products are applied like common paints: spray, roll, hands, paint-brush and on all surfaces
SHIELD COAT is an insulation coating fitted to solve problems of thermal and acoustic insulation, also in hard and extreme situations.
Flexible, light, ecologic, environnement friendly, non-toxic, water-based, easy in the application, even in vertical position, for the insulation of roofs, wallscivil structures, tanks, pipings, ecc.
FOAMING VERSIONS:
Volume Expansion: 500%Working Temperature from -100°C to +250°C till 350°CHigh resistance to direct fireHigh level of acuoustic reductionHigh reduction of vibrations
Producs are:
|
IMPORTANT TO UNDERLINE
|
||||||||||||
Spray - Brush - Rolls
TECHNICAL DATA - SPRAY SYSTEM APPLICATION
Video SHIELD COAT
Miscelazione prodotto / Product mixing
Collettore Scarico Motori / Exhaust Engine Systems
Video collettore scarico motiri / Exhaust system application
Applicazione edile / Civil application
Applicazioni a pistola / Spray application
Technical Data
Max temperature | 250°C till 350°C |
Thermal Conduttivity | 0,020 W/Mk |
VOC content | Zero |
Weight | 0,60 kg / weet – 0,20 kg dry |
Fire spread – Flame spread | None - Class A1 |
Coat thickness | 3 – 4 mm |
Coverage: liters per square meters | From 0,6 to 1 lt / kg per mm of thickness |
THERMAL TEST

Thickness 8 mm | Temperature 200 ° C | we obtain | 52° C |
Thickness 8 mm | Temperature 400 ° C | we obtain | 74° C |
Thickness 8 mm | Temperature 500 ° C | we obtain | 91° C |
Thickness 8 mm | Temperature 600 ° C | we obtain | 116° C |
ACOUSTIC TEST
Acoustic reduction with the product covering: Frequence Hz

ACOUSTICAL REDUCTION | |||||||
Reduction in Decibel according with the frequence | |||||||
Frequence Hz | 188 | 366 | 585 | 881 | 1000 | 3000 | 5000 |
8 mm of thichness | 9,3 | 11,5 | 10,7 | 11,6 | 10,8 | 10,9 | 11 |
4 mm of thickness | 4 | 5,8 | 5,3 | 5,7 | 5,7 | 5,7 | 5,8 |
Plain pannel (no coating) | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
CHIMICAL RESISTANCE:
TEST CERTIFICATE | ||
CHEMICAL RESISTANCE | ||
TYPE | DETAILS | COMMENTS |
DIESEL | 100 % CONC. / 0,5 ml | MODERATE SOFTENING NO SWELLING NO BLISTERING NO COLOR CHANGE |
SULPHURIC ACID | 10 % CONC. / 0,5 ml | |
GASOLINE - UNLEADED | 100 % CONC. / 0,5 ml | |
HYDROCHLORIC ACID | 10 % CONC. / 0,5 ml | |
10W / 30W MOTOR OIL | 100 % CONC. / 0,5 ml | |
SODIUM HYDROXIDE | 10 % CONC. / 0,5 ml |
These thermal insulation systems, can be applied on any surface?
Thermal insulation systems Shield Coat can be applied on any type of surface: glass, wood, concrete, masonite, metals in general. In the case of applications particularly smooth surfaces, we recommend applying a primer designed to increase grip. In case of application of Shield Coat 600 version, the application of the primer is highly recommended, either to increase the grip both to improve the behavior of the system to the thermal expansion of the underlying support. Always for the 600° C system is strongly recommended the application of consolidating finish, in order to give more structure to the system, since you may experience weakness in the presence of strong vibrations.
What is thermal reduction?
With a thickness of 8 mm, it is possible to achieve a reduction of 80%.
What is the recommended thickness of product to have an excellent thermal protection?
Thickness is a function of temperature to be obtained. Recommended minimum thickness is 6 mm, which can be obtained with 2 coats of product application. This product is very light and does not drip.
How do I apply these products?
Our thermal insulation systems can be applied as a common paint: spray, brush, roller, spatula.
How long will it take for the product to dry?
The total time total of polymerisation of the product is 24-48 hours, depending on weather conditions. Between a hand and the other simply wait 2-4 hours, to allow the surface to dry (out-dust)
How these products behave in the presence of strong corrosion?
Our systems Shield Coat, solve the problem of corrosion under insulation. They are also highly effective as an anti-condensation, mould, with the possibility to save costs in not having to apply distinct products, even in very difficult situations and critical applications
Are toxic products?
Our products are absolutely non-toxic. Are all water based with zero VOCS.
What is the reaction-to-fire?
Our thermal insulating are self-extinguishing, we also have fire-retardant versions in class REI.
It is possible to combine the different systems?
Shield Coat Systems con be overlap each other in order to create systems to various situations.
Some examples:
You can apply 4 mm of insulation Shield Coat 250 or 600 mm and 4 mm of Shield Coat Fireproof in order to have have a thermal protection and fire protection.
You can apply 6 mm of insulation Shield Coat 250 or 600 mm and with 2 mm of consolidating finish / high-strenght finish, to have a thermal protection combined with a high quality finish and excellent mechanical resistance and with the color you want.
Our engineers will assess the best combination in order to solve your problems.
THERMAL INSULATION
THERMAL INSULATING COATING
INSULATION COATING
INSULATING COATING
THERMAL COATING
ANTI-CONDENSATION
protection from Corrosion Under Insulation
Corrosion Prevention Coating
THERMAL INSULATION
SYSTEMSFIRE STOPPING
INSULATIONFIRE RESISTANCE COATING
FIRE RESISTANCE INSULATION
CRYOGENIC INSULATION
THERMAL PROTECTION
INSULATION PROTECTION
THERMAL RESISTANCE
CIVIL INSULATION
RESIDENTIAL INSULATION
INSULATION PAINTINGHIGH TEMPERATURE INSULATIONS
TANK INSULATIONTANK THERMAL INSULATION
HEAT EXCAHNGER TERMAL INSUALTIONVALVES INSUALTION
PIPING INSULATION
OWNS INSUALTION
PETROCHEMICAL INSUALTION
FOUNDRY INSULATION
AUTOMOTIVE INSUALATION
EXHAUST SYSTEM INSULATION
ENGINE THERMAL INSULATION
MARINE INSUALTION
ANTICONDENSATION
ANTICORROSION PROTECION
ANTICORROSION INSULATION
ROOF THERMA INSUALTION
WALL THERMAL INSUALTION
SOLAR INSUALTION
SOLAR PANEL THERMAL INSUALTION